Optix Logo

OPTIX Measurement Laboratory

Technology Park OPTIX  has on its disposal the unique for Balkan Peninsula systems DT 1500  test system and LAFT for checking the parameters of thermal vision devices. The extremely important asset for the company is a guarantor of high-tech solutions in the design and manufacture of thermal imaging equipment. The availability of equipment for measurement of parameters of laser rangefinders and image intensifier tubes, used in the night vision devices, creates real preconditions for production of even more high quality and competitive devices and systems.

Possibilities of equipment in the measurement laboratory:

DT 1500 test system provides measurement for the following parameters of the thermal vision devices:
1.  MRTD;
2.  MDTD /option/;
3.  Noise parameters /NETD, FPN, non uniformity/;
4.  SiTF;
5.  MTF;
6.  Distortion;
7.  FOV;
8.  AutoMRTD /option/;
9.  SRF /option/;
10. Dead pixels /option/;
11. 1/f noise /option/;
12. 3D noise /option/;
13. PVF /option/;
14. Response function /option/.

LAFT provides measurement for the following parameters of the termal vision devices:

1. MRTD, MDTD /basic version/;
2. MRTD, MDTD, MTF, NETD, FPN, non-uniformity, distortion, FOV /extended version/;
3. SiTF, SRF /option/.

ITS test station provides measurement for the parameters of image intensifying tubes:

1. resolution;
2. modulation transfer function /MTF/;
3. signal to noise /SNR/;
4. dark and bright spots;
5. useful cathode diameter;
6. output brightness non-uniformity;
7. gross distortion and shear distortion;
8. image alignment;
9. halo.

NVT test station provides measurement for the parameters of night vision devices:

1. focus;
2. resolution;
3. screen quality;
4. system gain;
5. field of view.

LT test station may be used to measure the parameters of laser rangefinders:

1. pulse energy;
2. pulse width;
3. pulse repetition frequency;
4. divergence.